Magnum Energy ME-RC Manual del operador

Busca en linea o descarga Manual del operador para Controles remotos Magnum Energy ME-RC. Magnum Energy ME-RC Operator`s manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Operator’s Manual

ME Series Inverter / Chargers Operator’s Manual

Pagina 2 - SAVE THESE INSTRUCTIONS

1. INTRODUCTION 5. The ME Series Inverter/Charger The ME Series inverter/charger is designed to allow easy access to wiring, circuit breakers, control

Pagina 3 - IMPORTANT

2. INSTALLATION 1. Unpacking and Inspection Carefully remove the ME Series inverter from its shipping container and inspect all contents. If items ap

Pagina 4 - Magnum Energy

2. INSTALLATION 2. Pre-Installation, continued Hardware / Materials Required Conduit, strain - reliefs and appropriate fittings 1/4" mounting bo

Pagina 5 - Table of Contents, continued

2. INSTALLATION 2. Pre-Installation, continued Torque Requirements Torque all AC wiring connections to 16 inch pounds. Torque DC cable connections t

Pagina 6 - 2. Standard Features

2. INSTALLATION Mounting Screw Placements Figure 4 ME Series Inverter / Charger Base Plate Inverter ME1512 ME2012 ME2512 ME3012 DC Rating 150 am

Pagina 7 - ME Series Inverter / Charger

10 Ó 2003 - Magnum Energy, Inc.

Pagina 8 - 4. Appliances and Run Time

2. INSTALLATION 3. Installation NOTE: Read all instructions and cautionary markings located at the beginning of this manual and in the pre- installat

Pagina 9

2. INSTALLATION 3. Installation, continued Battery Cables and Sizing Select the correct battery cables for the installation from the table. It is im

Pagina 10

2. INSTALLATION 3. Installation, continued Battery Wiring WARNING: During the installation and wiring process, cover exposed battery cable ends with

Pagina 11 - 2. Pre-Installation

2. INSTALLATION TO 12 VDC INVERTER - > Figure 7 Parallel Battery Wiring individual battery capacity = 100 AHr @ 12 VDC combined battery capacity =

Pagina 12

IMPORTANT SAFETY INSTRUCTIONS This manual contains important safety instructions that must me followed during the installation and operation of this

Pagina 13

combined battery capacity = 400 AHr @ 12 VDC 14 Ó 2003 - Magnum Energy, Inc.

Pagina 14

2. INSTALLATION 3. Installation, continued Series Connection (four 6 VDC batteries to create a 24 VDC bank) A series connection combines overall bat

Pagina 15

2. INSTALLATION In - line fuse ~ > + TO 12 VDC INVERTER - > Figure 10 Parallel Battery Wiring - Fuse Placement - Figure 11 Series Battery Wir

Pagina 16 - 3. Installation

2. INSTALLATION 3. Installation, continued DC Fuse Block A fuse or circuit breaker must be located within 18 inches of the battery to protect the DC

Pagina 17 - 3. Installation, continued

Ó 2003 - Magnum Energy, Inc. 17

Pagina 18

2. INSTALLATION DC Chassis Ground Figure 13 ME Series Inverter / Charger - AC Wiring AC Output 2 Circuit Breaker (on dual output models only) AC Outp

Pagina 19

2. INSTALLATION 3. Installation, continued AC Wiring WARNING: De -energize all sources of power including batteries (DC), shore power (AC), and AC ge

Pagina 20

2. INSTALLATION Figure 15 ME Series Inverter / Charger - AC Wiring Diagram (located on back of cover plate) Figure 16 ME Series Inverter / Charger

Pagina 21

2. INSTALLATION 3. Installation, continued Wiring the Inverter AC Input (refer to diagrams on the following pages) Remove the chassis AC access cove

Pagina 22

Figure 17a Typical Wiring - Single IN / Single OUT (120 VAC) Figure 18a Typical Wiring - Single IN / Dual OUT (120 VAC) Figure 19a Typical Wiring

Pagina 23

IMPORTANT BATTERY SAFETY INSTRUCTIONS Wear eye protection such as safety glasses when working with batteries. Remove all jewelry such as rings, watch

Pagina 24

2. INSTALLATION Inverter/Charger AC Main Breaker Panel AC Input Wiring 30 Amp AC Sub-panel AC Output Wiring Air Conditioning

Pagina 25

2. INSTALLATION Stack Port Magnum Net Port Remote Port Battery Temp Sensor Port Figure 20 ME Series Inverter / Charger - Option Connection Ports 24

Pagina 26

2. INSTALLATION 4. Options Battery Temperature Sensor Installation and Wiring Attach the ring terminal end of the Battery Temperature Sensor to the

Pagina 27

Ó 2003 - Magnum Energy, Inc.

Pagina 28

2. INSTALLATION 5. Start-up and Test Connecting the Batteries to the Inverter After all electrical connections have been completed, connect the batt

Pagina 29

Configuring the Inverter The ME Series inverter/charger must be configured for Low Battery Cutoff (LBCO), Shore Power Current, Charger Amps, Battery S

Pagina 30

Table 5 - Factory Default Settings Function Search LBCO Battery Bank Battery Type Charge Rate Contrast Default 5 watts 11 VDC 400 AHr Liquid Lead A

Pagina 31

3. OPERATION Charging / Inverting LED Figure 21 ME Series Inverter / Charger - LED Indicator 28 Ó 2003 - Magnum Energy, Inc.

Pagina 32 - 4. Options

3. OPERATION 1. Operating the Inverter The ME Series inverter/charger has two modes of operation: INVERTER (providing power to your appliances from t

Pagina 33

3. OPERATION Figure 22 ME Series Inverter / Charger - Fault Conditions Figure 23 Optional ME Series Remote Control - Fault Conditions 30 Ó 2003

Pagina 34 - 5. Start-up and Test

Magnum Energy ME Series Inverter / Chargers Table of Contents Section Description Page 1. Introduction 1 1. Features and Benefits 1 2. Standard F

Pagina 35

3. OPERATION 1. Operating the Inverter, continued Fault or Alarm Conditions The inverter monitors the AC Shore Power, the batteries and itself. Whene

Pagina 36

4. TROUBLESHOOTING 1. Basic Troubleshooting The ME Series inverter/ charger is a fairly simple device to troubleshoot. There are only two active circu

Pagina 37

5. PREVENTIVE MAINTENANCE 1. Recommended Inverter and Battery Care The ME Series inverter/ charger is designed to provide you with years of trouble f

Pagina 38 - 1. Operating the Inverter

6. SPECIFICATIONS ME Series Specifications ME2012 ME2512 ME3012 12 VDC 10.8-15.5 VDC 12 VDC 10.8-15.5 VDC 12 VDC 10.8-15.5 VDC 2000 watts 4000 watts

Pagina 39

7. WARRANTY 36 Month Limited Warranty Magnum Energy, Inc., warrants the ME Series Inverter / Charger to be free from defects in material and workmans

Pagina 40

Remote Control for ME Series Inverter/Chargers Operator’s Manual

Pagina 41 - 1. Basic Troubleshooting

Remote Control for ME Series Inverter/Chargers Table of Contents Section Page 1. Overview 2 2. Installation 3 3. Operation 4 Front Panel 5 Rotary

Pagina 43 - ME Series Specifications

1. Overview IMPORTANT SAFETY INFORMATION • This product must be installed by a qualified technician in accordance with all applicable electrical code

Pagina 44 - 36 Month Limited Warranty

2. Installation Installing the ME Series Remote Control 1. Determine a suitable location to mount the remote control. It must be located in a clean,

Pagina 45 - Inverter/Chargers

Table of Contents, continued Section Description Page 2. Installation, continued 4. Options 25 Battery Temperature Sensor Installation and Wirin

Pagina 46

3. Operation Figure 2 Remote Control - Font Panel Ó 2003 - Magnum Energy, Inc. 4

Pagina 47

3. Operation, continued ME Series Remote Control - Front Panel The remote control is equipped with a wide range of easy-touse switches and displays,

Pagina 48 - IMPORTANT SAFETY INFORMATION

Liquid Lead Acid (Flooded) Bulk 14.6 VDC Absorption 14.6 VDC Float 13.4 VDC Equalize 15.5 VDC GEL Bulk 14.1 VDC Absorption 14.1 VDC Float 13.6 VDC

Pagina 49 - 2. Installation

Chart 2 - Absorption Times (determined by battery bank size selection) Chart 3 - Factory Default Settings Ó 2003 - Magnum Energy, Inc. Battery Siz

Pagina 50 - 3. Operation

3. Operation, continued Soft Keys, continued: Setup – Configures the inverter/charger. Options include: • Search Used to set the search watts at whi

Pagina 51 - 3. Operation, continued

3. Operation, continued LEDs The remote contains the following LEDs to indicate various modes of operation. PWR (green): OFF - NO AC power from inver

Pagina 52

3. Operation, continued LCD DISPLAY INVERTING: OFF - Unit is “OFF” with no shore or generator AC power applied. Search – Unit is in search mode. AC l

Pagina 53

3. Operation, continued Float – At the end of absorption time, the charger reduces the charge voltage to the float voltage setting for the battery typ

Pagina 54

4. Troubleshooting and Specifications Fault Conditions Low Battery – The unit has shut down because the battery voltage is below the set point in LBCO

Pagina 55

5. Warranty 36 Month Limited Warranty Magnum Energy, Inc., warrants the ME Series Remote Control to be free from defects in material and workmanship

Pagina 56

1. INTRODUCTION 1. Features and Benefits Congratulations on your purchase of the ME Series inverter/charger from Magnum Energy. The ME Series is a “n

Pagina 57

Magnum Service Manual REV 1.0 12/03 INDEX 1.0 Troubleshooting 2.0 Repairing 2.1 Top Cover Removal 2.2 AC Board 2.3 AC Breakers 2.4 Fet Board 2.6 D

Pagina 58

1.0 TROUBLESHOOTING 1.1 ME SERIES 1.2 RD SERIES 1.3 REMOTE

Pagina 59 - 5. Warranty

2.0 REPAIRING OVERVIEW

Pagina 61 - 1.0 TROUBLESHOOTING

1.1 TOP COVER REMOVAL 2.1.a Top cover is attached with 6 - #10 x 5/8 Torx screws (#25 bit) and 1- #6 x 1/2 Torx screw (#15 bit). Remove all seven scre

Pagina 62 - 2.0 REPAIRING

wires can lead to instant FET board failure upon connecting ac power to the unit. WIRING COLOR CODE: White – Neutral IN (2 wires) Black – AC Hot IN 1

Pagina 63

2.3 AC BREAKERS 2.3.a Remove top cover per 2.1 2.3.b Remove 4- #6 x ½ Torx screws from corners of ac board and lift board slightly (see 2.2 for screw

Pagina 64 - 1.1 TOP COVER REMOVAL

2.4.e Install new control board in reverse order making sure to line up connector on board edge with FET board connector before pushing down on contr

Pagina 65 - IN 2 Blue – Hot OUT 2

2.6 FET BOARD 2.6.a Remove top cover per 2.1 2.6.b Remove control board per 2.4 2.6.c Remove DC Plate per 2.5

Pagina 66 - 2.4 CONTROL BOARD

2.6.d Remove 2 - ¼ x 20 bolts and nuts from FET board wiring bundles to transformer lugs 2.6.e Remove 1 - #6 x ½ Torx screw from outside edge of FET

Pagina 67

1. INTRODUCTION Figure 1 ME Series Inverter / Charger Ó 2003 - Magnum Energy, Inc. 2

Pagina 68 - 2.6 FET BOARD

Use a utility knife or sharp chisel to cut temp sensor loose then clean remaining silicon from transformer 2.7.d Remove 4 corner Phillips head screw

Pagina 69

2.6 FANS 2.8.a Remove Top Cover per 2.1 2.8.b Remove 1 - #6 x ½ Torx screw from fan bracket 2.8.c Bend fan bracket upward to remove fan 2.8.d Rei

Pagina 70

2.9 REMOTE 2.8.a Remove front knob (it may be necessary to pry slightly up on knob) 2.8.b Remove 2 Phillips head screws from back of remote 2.8.c

Pagina 76

1. INTRODUCTION 3. How an Inverter/Charger Works An inverter takes direct current (DC) from your batteries and turns it into alternating current (AC),

Pagina 77

1. INTRODUCTION 4 Power ON/OFF Switch Charging / Inverting LED Stack Port Magnum Net Port Remote Port Battery Temp Sensor Port Figure 2 ME Series Inve

Comentarios a estos manuales