2003 - Magnum Energy, Inc.
8
LEDs
The remote contains the following LEDs to indicate various
modes of operation.
POWER –
The green POWER LED indicates 120 VAC power is available
at HOT OUT 1 and HOT OUT 2 from either inverting, shore or
generator power.
FAULT –
The red FAULT LED indicates the inverter/charger has shut
down from one of the following conditions:
High Battery - Battery voltage exceeded 15.5 VDC
Low Battery – Battery voltage is below LBCO setting
Overtemp – Unit has exceeded maximum operating
temperature
AC Overload – AC loads exceeded unit’s output rating
CHARGER –
The green CHARGER LED indicates the charger is “ON.” The
charger’s output is determined by selections made in the
“Charge Rate” and “Shore” setup options. When the
CHARGER LED is blinking, it indicates a “reduced charge
rate” based on a low “Charge Rate” or “Shore” setting, or an
over temperature condition.
INVERTER –
The green INVERTER LED indicates the inverter is “ON.” If
AC power is available from shore or generator, then the
inverter is in “standby mode” indicated by a blinking LED.
In the event AC shore or generator power is lost, the in-
verter is standing by to power the connected loads from the
batteries.
3. Operation, continued
Figure 3
LEDs
Power LED
Fault LED
Charger LED
Inverter LED