2003 - Magnum Energy, Inc.
9
LCD DISPLAY
INVERTING:
OFF -
The unit is “OFF” with no shore or generator AC power
applied.
Search –
The unit is in search mode. AC loads are less than the
search watts setting.
Inverting –
The unit is inverting power from the batteries into 120 VAC
at its output.
CHARGING:
Bulk Charge –
The battery charger is delivering maximum current to the
batteries. The charger will remain in bulk charge until the
bulk charge voltage is achieved. See Chart 1.
NOTE: The maximum current can be reduced by adjusting
the battery charge rate and shore power settings using the
setup options.
Absorption –
Absorption charge is the second stage of charging and
indicates the bulk voltage for battery type selected has been
reached. The DC current will start to taper off in order to
maintain the bulk voltage setting. Absorption time is deter-
mined by battery bank size selection. See Chart 2.