2003 - Magnum Energy, Inc.
11
Specifications
Electrical Requirements 12 VDC
Controls Charger (ON/OFF),
Inverter (ON/OFF)
LED Indicators Power, Fault, Charger, Inverter
Soft Keys Shore, AGS, Meter, Setup, Tech
Selector Switch Rotary (press to accept)
Display LCD (2 line)
Cable type 4 wire twisted pair
Weight 0.5 lb (0.22 kg)
Dimensions 3.75" H x 5.75" W x 1.125" D
(9.5 cm H x 16.6 cm W x 2.9 cm D)
Cutout Dimensions 2.75" H x 4.75" W
(7 cm H x 12 cm W)
Specifications at 25 °C - subject to change without notice.
Fault Conditions
Low Battery –
The unit has shut down because the battery voltage is
below the set point in LBCO. It will automatically restart
when battery voltage rises above 12.4 VDC.
High Battery –
The unit has shut down because the battery voltage has
exceeded 15.5 VDC. It will automatically restart when the
battery voltage drops below 15.0 VDC.
Overtemp –
The unit has shut down because the temperature at the
transformer or FET board has exceed the safe temperature
operating range. It will automatically restart after unit cools
down.
AC Overload –
The unit has shut down because the AC load connected to
the inverter’s output exceeded its maximum output rating.
NOTE: When this occurs, reduce the load and MANUALLY
restart the unit.
4. Troubleshooting and Specifications