2. Configuration
Figure 1 - AGS Controller Configuration
(DIESEL/GAS and 12/24 V DC Operation)
1. Configuring the AGS Controller
The Magnum AGS Controller can be configured for 12 or 24 VDC
operation. It can also be configured for various diesel or gas
generator brands and models. The controllers default settings
are set for "12 VDC" and "Diesel" operation. If necessary, refer
to Table 1 (next page) to determine which setting is correct for
your system. To access the jumpers, remove the controllers
four cover screws.
For Onan Quiet Diesel generators, the controller is configured
with the "Diesel/Gas" jumper positioned over the two
left-hand pins as shown below (factory default).
For most "gas" as well as other diesel generators you must
configure the controller with the "Diesel/Gas" jumper
positioned over the two right-hand pins as shown below
For 12 Volt DC operation, the controller is configured
with the "12/24 V" jumper positioned over the two left-hand
pins as shown below (factory default).
For 24 Volt DC operation, you must configure the
controller with the "12/24 V" jumper positioned over the two
right-hand pins as shown below.
Onan Quiet Diesel
(default)
Other Diesel
and Gas
Controller and Internal Board
Remove the four
cover screws
12/24 V
Jumper
12 VDC Operation
(default)
24 VDC Operation
DIESEL/GAS
Jumper
Not Used